VMD-L Mailing List
From: Axel Kohlmeyer (akohlmey_at_gmail.com)
Date: Mon Oct 04 2010 - 16:02:13 CDT
- Next message: Pat Yee: "RE: trouble with measure hbonds"
- Previous message: Eduard Schreiner: "Re: trouble with measure hbonds"
- In reply to: Charlotte Siska: "trouble with measure hbonds"
- Next in thread: Pat Yee: "RE: trouble with measure hbonds"
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ] [ attachment ]
On Mon, 2010-10-04 at 14:01 -0600, Charlotte Siska wrote:
charlotte,
> Whenever I try to use measure hbonds I get nothing but three empty
> lists. I have made sure that the index I use for my selection does not
> have hydrogen atoms, which was recommended in other postings in the
> mailing list. I think I am missing something.
>
> General code:
>
> measure hbonds 3.5 30 [atomselect top "index 5"]
>
> Any help would be greatly appreciated!
your selection has only one atom?
please reread the documentation. you have to have
to provide hydrogen bond donors and acceptors either
combined in one selection or as two selections.
http://www.ks.uiuc.edu/Research/vmd/current/ug/node133.html
cheers,
axel.
>
> Charlotte Siska
-- Dr. Axel Kohlmeyer akohlmey_at_gmail.com http://sites.google.com/site/akohlmey/ Institute for Computational Molecular Science Temple University, Philadelphia PA, USA.