VMD-L Mailing List
From: Axel Kohlmeyer (akohlmey_at_cmm.chem.upenn.edu)
Date: Fri May 23 2008 - 18:59:33 CDT
- Next message: politr_at_huji.ac.il: "How to discard certain atoms"
- Previous message: Christopher Gillespie: "Measure gofr with large DCD files (Possibly use bigdcd ???)"
- In reply to: Christopher Gillespie: "Measure gofr with large DCD files (Possibly use bigdcd ???)"
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ] [ attachment ]
On Fri, 23 May 2008, Christopher Gillespie wrote:
CG> Hello all,
hello chris,
CG> I have been searching through the lists looking for an answer to this. I
CG> want to get the gofr for the ions in my system relative to specific parts of
CG> my protein, which I can do perfectly fine with my small systems. On my
CG> systems approaching 100k atoms the dcd files are on the order of 18-20GB.
CG> So I break these up into 4 smaller dcd files and try to load the dcd but it
CG> is still to big to load directly. I thought about using bigdcd for this but
CG> I am not sure how a gofr calc would get handled since the examples of COM or
CG> RMSD do not require knowledge of the counts from each previous frame.
the same is true for the g(r). it is only the "spatial" correlation
function not a time-correlation. so either using bigdcd and then
"measure gofr" on a single frame as well as operating on chunks of
arbitrary size and then averaging over the results should work fine.
cheers,
axel.
p.s.: please make sure that your "delta r" parameter is small enough.
(e.g. 0.001). i've seen a few (unusual) example systems recently where
the results were not correct with larger delta-r. there has to be a bug
in the construction of the histograms (e.g. a mixup of < and <= or
something similar), but i have not yet been able to identify it.
CG>
CG> Is there a way to either use bigdcd with gofr or combine gofrs from smaller
CG> dcd files to make a gofr for the entire run?
CG>
CG> So far I break it down to 1ns parts for a 4ns production run, but that is
CG> still too large.
CG>
CG> Thanks
CG>
CG> Chris
CG>
-- ======================================================================= Axel Kohlmeyer akohlmey_at_cmm.chem.upenn.edu http://www.cmm.upenn.edu Center for Molecular Modeling -- University of Pennsylvania Department of Chemistry, 231 S.34th Street, Philadelphia, PA 19104-6323 tel: 1-215-898-1582, fax: 1-215-573-6233, office-tel: 1-215-898-5425 ======================================================================= If you make something idiot-proof, the universe creates a better idiot.
- Next message: politr_at_huji.ac.il: "How to discard certain atoms"
- Previous message: Christopher Gillespie: "Measure gofr with large DCD files (Possibly use bigdcd ???)"
- In reply to: Christopher Gillespie: "Measure gofr with large DCD files (Possibly use bigdcd ???)"
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ] [ attachment ]