VMD-L Mailing List
From: Axel Kohlmeyer (axel.kohlmeyer_at_theochem.ruhr-uni-bochum.de)
Date: Wed Apr 21 2004 - 15:47:17 CDT
- Next message: Dallas Warren: "Re: Rendering of screen/display different"
- Previous message: John Stone: "Re: error with top2psf"
- In reply to: John Stone: "Re: error with top2psf"
- Next in thread: Marc Baaden: "Re: error with top2psf"
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ] [ attachment ]
davide,
try using the preprocessed topology file,
i.e. the one you get from using grompp's -pp option.
axel.
On Wed, 21 Apr 2004 13:40:22 -0500 John Stone wrote:
>
> Davide,
> I'd suggest emailing Marc Baaden and see if he has a suggestion since
> he's the one that wrote the script. I don't personally know anything
> about Gromacs yet, but if that doesn't pan out, the next option would be
> for someone to write a real Gromacs .top reader plugin for VMD, which is
> probably the best long-term solution. Marc's email is on that top2psf page
> I sent previously.
>
> John Stone
> vmd_at_ks.uiuc.edu
>
> On Wed, Apr 21, 2004 at 01:04:51PM +0200, davide.ruffoni wrote:
> > Hi, I'm using top2psf script. The problem is that the waters molecules inserted
> > by gromacs in the topology file (.top) are not converted in the psf, thus when
> > I try to merge the coordinates (coor.trr) with the topol.psf I get as error:
> > incorrect number of atom. How to solve this problem?
> > Thanks in advance
> > Davide
> >
> >
> >
> >
> > --
> > Email.it, the professional e-mail, gratis per te: http://www.email.it/f
> >
> > Sponsor:
> > Natsabe.it la pił grande erboristeria multimarca online.
> > Solo prodotti di altissima qualitą.
> >
> > Clicca qui: http://adv.email.it/cgi-bin/foclick.cgi?mid=1308&d=21-4
>
> --
> NIH Resource for Macromolecular Modeling and Bioinformatics
> Beckman Institute for Advanced Science and Technology
> University of Illinois, 405 N. Mathews Ave, Urbana, IL 61801
> Email: johns_at_ks.uiuc.edu Phone: 217-244-3349
> WWW: http://www.ks.uiuc.edu/~johns/ Fax: 217-244-6078
>
-- ======================================================================= Axel Kohlmeyer e-mail: axel.kohlmeyer_at_theochem.ruhr-uni-bochum.de Lehrstuhl fuer Theoretische Chemie Phone: ++49 (0)234/32-26673 Ruhr-Universitaet Bochum - NC 03/53 Fax: ++49 (0)234/32-14045 D-44780 Bochum http://www.theochem.ruhr-uni-bochum.de ======================================================================= If you make something idiot-proof, the universe creates a better idiot.
- Next message: Dallas Warren: "Re: Rendering of screen/display different"
- Previous message: John Stone: "Re: error with top2psf"
- In reply to: John Stone: "Re: error with top2psf"
- Next in thread: Marc Baaden: "Re: error with top2psf"
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ] [ attachment ]