On Mon, Jan 23, 2012 at 1:45 PM, jeela keel <jeela22_at_gmail.com> wrote:
> Hi
>
> the script is the following
> setting the number of frames
> set sel1 [atomselect top "protein"]
> #set sel2 [atomselect top "resname SOL "]
> set sel2 [atomselect top "resname SOL and pbwithin 4.00 of protein
> "]
>
> set gr1 [measure gofr $sel1 $sel2 delta .1 rmax 10.0 usepbc 1
> selupdate 1 first 1 last $number_frame step 1]
> set r [lindex $gr1 0]
> set gr2 [lindex $gr1 1]
> set igr [lindex $gr1 2]
> set i 0
> foreach j $r k $gr2 l $igr {
> puts $outfile1 "$j $k $l"
>
this is not a complete script and doesn't work.
axel.
> thank you jeela
>
> On Mon, Jan 23, 2012 at 12:55 PM, Axel Kohlmeyer <akohlmey_at_gmail.com> wrote:
>>
>> On Mon, Jan 23, 2012 at 12:35 PM, jeela keel <jeela22_at_gmail.com> wrote:
>> > Hi All,
>> >
>> > I used a different dcd file that has less frames (only 263). This time
>> > it
>> > gave same error but in the frame 262 before the last one.
>> > is it possible that my sections are causing the problem since the
>> > measure
>> > command is using the selections? I am selecting the protein and the
>> > water surrounding the protein.
>> >
>> > ERROR) measure gofr: bad frame range given. max. allowed frame#: 262
>>
>> a-ha! yes. if you have 263 frames, the last frame is frame number 262.
>> the frame numbers start from 0. if you want to use an explicit number of
>> frames, then you have to subtract 1 from the total number of frames to
>> get the last frame number.
>>
>> axel.
>>
>>
>> >
>> > Thank you
>> >
>> > Jeela
>> >
>> >
>> >
>> > On Mon, Jan 23, 2012 at 12:18 PM, jeela keel <jeela22_at_gmail.com> wrote:
>> >>
>> >> yes I am doing similar way to get the number of frames.
>> >>
>> >> jeela
>> >>
>> >>
>> >> On Mon, Jan 23, 2012 at 11:01 AM, John Stone <johns_at_ks.uiuc.edu> wrote:
>> >>>
>> >>>
>> >>> Are you correctly querying the number of frames with something like:
>> >>> set number_frame [molinfo top get numframes]
>> >>>
>> >>> Cheers,
>> >>> John Stone
>> >>> vmd_at_ks.uiuc.edu
>> >>>
>> >>> On Mon, Jan 23, 2012 at 10:56:43AM -0500, jeela keel wrote:
>> >>> > On Mon, Jan 23, 2012 at 10:29 AM, Axel Kohlmeyer
>> >>> > <akohlmey_at_gmail.com>
>> >>> > wrote:
>> >>> >
>> >>> > isn't the error message is self-explanatory?
>> >>> > your argument to the "last" flag is obviously incorrect.
>> >>> >
>> >>> > axel.
>> >>> > >
>> >>> > Hi Axel
>> >>> >
>> >>> > set gr1 [measure gofr $sel1 $sel2 delta .1 rmax 10.0 usepbc
>> >>> > 1 selupdate 1 first 1 last $number_frame step 1]
>> >>> >
>> >>> > Thank you for your suggestion, I am using the last number for
>> >>> > the
>> >>> > frames which is 1000 frames but it stops in frame 500 and give
>> >>> > me
>> >>> > the
>> >>> > error
>> >>> > jeela
>> >>> >
>> >>> > --
>> >>> > Dr. Axel Kohlmeyer
>> >>> > akohlmey_at_gmail.com http://goo.gl/1wk0
>> >>> >
>> >>> > College of Science and Technology
>> >>> > Temple University, Philadelphia PA, USA.
>> >>>
>> >>> --
>> >>> NIH Resource for Macromolecular Modeling and Bioinformatics
>> >>> Beckman Institute for Advanced Science and Technology
>> >>> University of Illinois, 405 N. Mathews Ave, Urbana, IL 61801
>> >>> http://www.ks.uiuc.edu/~johns/ Phone: 217-244-3349
>> >>> http://www.ks.uiuc.edu/Research/vmd/ Fax: 217-244-6078
>> >>
>> >>
>> >
>>
>>
>>
>> --
>> Dr. Axel Kohlmeyer
>> akohlmey_at_gmail.com http://goo.gl/1wk0
>>
>> College of Science and Technology
>> Temple University, Philadelphia PA, USA.
>
>
-- Dr. Axel Kohlmeyer akohlmey_at_gmail.com http://goo.gl/1wk0 College of Science and Technology Temple University, Philadelphia PA, USA.
- Next message: Axel Kohlmeyer: "Re: ERROR) measure gofr: bad frame range given. max"
- Previous message: jeela keel: "Re: ERROR) measure gofr: bad frame range given. max"
- In reply to: jeela keel: "Re: ERROR) measure gofr: bad frame range given. max"
- Next in thread: jeela keel: "Re: ERROR) measure gofr: bad frame range given. max"
- Reply: jeela keel: "Re: ERROR) measure gofr: bad frame range given. max"
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ] [ attachment ]