From: JC Gumbart (gumbart_at_physics.gatech.edu)
Date: Sun Oct 18 2020 - 18:37:03 CDT

Lokendra,

In CHARMM, non-polar hydrogens are assigned 0.09 by default, and the associated carbons are often made -0.18 or -0.27 accordingly. Going beyond this, I recommend looking at published examples, e.g., the CHARMM36 lipid force field, for ideas: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2922408/ <https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2922408/>

Best,
JC

> On Oct 13, 2020, at 6:55 PM, Lokendra Poudel <poudel_2039_at_tamu.edu> wrote:
>
> Hi Everyone!
>
> I am generating a CHARMM force field for a drug from VMD's FFTK. This drug is extremely hydrophobic/insoluble in water. Is the step of generating water interaction of QM data then charge optimization necessary or not to my molecules? since it is extremely hydrophobic. please advise me.
>
> Best regards