VMD-L Mailing List
From: John Stone (johns_at_ks.uiuc.edu)
Date: Fri Mar 11 2005 - 13:38:23 CST
- Next message: Philip Blood: "RE: limit on segment atom number in solvate and autoionize"
- Previous message: Philip Blood: "RE: limit on segment atom number in solvate and autoionize"
- In reply to: Philip Blood: "RE: limit on segment atom number in solvate and autoionize"
- Next in thread: Philip Blood: "RE: limit on segment atom number in solvate and autoionize"
- Reply: Philip Blood: "RE: limit on segment atom number in solvate and autoionize"
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ] [ attachment ]
Phil,
Can you tell me what error message(s) if any you are getting
when you try to do this? It should work fine as far as I know.
If you encounter a problem with the number of atoms in a segment,
number of segments, etc, they are likely to be issues with the
'psfgen' plugin, not with the solvate/autoionize plugins themselves,
since they use psfgen for most of the heavy lifting they do.
If you can send me more information on what's happening, it'll
help narrow down if this is in fact 'psfgen' or some buglet in
the other plugins you mentioned.
John Stone
vmd_at_ks.uiuc.edu
On Fri, Mar 11, 2005 at 12:18:22PM -0700, Philip Blood wrote:
> Correction: I thought I had seen this behavior in autoionize, but it
> looks like it only occurs in the solvate plugin. I am using VMD 1.83
> and running solvate from the command line.
>
> Phil
>
> -----Original Message-----
> From: owner-vmd-l_at_ks.uiuc.edu [mailto:owner-vmd-l_at_ks.uiuc.edu] On Behalf
> Of Philip Blood
> Sent: Friday, March 11, 2005 10:53 AM
> To: vmd-l_at_ks.uiuc.edu
> Subject: vmd-l: limit on segment atom number in solvate and autoionize
>
> Hi,
>
> The solvate and autoionize plugins can only read in coordinates for 999
> atoms in a given segment even though the charm default is (a much more
> convenient) 9999. Is there any way around this limitation besides
> chopping up the system into segments of 999? Is there a reason why it
> is done this way and could it be easily changed?
>
> Thanks,
> Phil Blood
-- NIH Resource for Macromolecular Modeling and Bioinformatics Beckman Institute for Advanced Science and Technology University of Illinois, 405 N. Mathews Ave, Urbana, IL 61801 Email: johns_at_ks.uiuc.edu Phone: 217-244-3349 WWW: http://www.ks.uiuc.edu/~johns/ Fax: 217-244-6078
- Next message: Philip Blood: "RE: limit on segment atom number in solvate and autoionize"
- Previous message: Philip Blood: "RE: limit on segment atom number in solvate and autoionize"
- In reply to: Philip Blood: "RE: limit on segment atom number in solvate and autoionize"
- Next in thread: Philip Blood: "RE: limit on segment atom number in solvate and autoionize"
- Reply: Philip Blood: "RE: limit on segment atom number in solvate and autoionize"
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ] [ attachment ]