From: Vlad Cojocaru (vlad.cojocaru_at_mpi-muenster.mpg.de)
Date: Tue Jan 15 2019 - 07:29:02 CST
Dear NAMD users and developers,
I just noticed some potential mistakes in the NAMD user guide in the
section "accelerated MD".
In the description of the "accelMDdual", "accelMDTE" and "accelMDTalpha"
parameters, it is written that the second boost is applied on the
"Total-Dihedral" potential. However, in the dual boost flavor of aMD, as
described by Hamelberg et al (J.Chem.Phys. 2007) one boost is applied on
the DIHEDRAL energy and one on the total potential energy (and not on
the Total - Dihedral) .... Right ?
Assuming that the code applies the boosts correctly, it would be great
if the user guide is also corrected because it may induce confusion
especially for people new to the method.
Best wishes
Vlad
-- Vlad Cojocaru, PD (Habil.), Ph.D. ----------------------------------------------- Project Group Leader Department of Cell and Developmental Biology Max Planck Institute for Molecular Biomedicine Röntgenstrasse 20, 48149 Münster, Germany ----------------------------------------------- Tel: +49-251-70365-324; Fax: +49-251-70365-399 Email: vlad.cojocaru[at]mpi-muenster.mpg.de http://www.mpi-muenster.mpg.de/43241/cojocaru
This archive was generated by hypermail 2.1.6 : Thu Dec 31 2020 - 23:17:09 CST