From: Marcos Sotomayor (sotomayo_at_ks.uiuc.edu)
Date: Fri Nov 04 2005 - 15:29:52 CST
you could also use atomselections and tcl commands to get the appropriate 
vector as in the third part of the NAMD tutorial
http://www.ks.uiuc.edu/Training/Tutorials/namd/namd-tutorial-html/index.html
For instance, you can type in the Tk Console (Extensions menu of VMD)
set lig [atomselect top "chain X"] 
set cav [atomselect top "resid Y"]
set ligcm [measure center $lig]
set cavpos [lindex [$cav get {x y z}] 0]
vecnorm [vecsub $cavpos $ligcm]
Where  X is the chain label of the ligand and Y is some residue close to 
the other point.
Marcos
On Fri, 4 Nov 2005, JC Gumbart wrote:
> You will need to find a point in this cavern.  You can use 0 - Query and then 
> click on an atom near the center of this to find its coordinates.  Then you 
> can define a vector between the two points.
>
> To visualize it, you can use the tcl command "draw line {point 1} {point 2} 
> width 10".
>
> On Nov 4, 2005, at 3:01 PM, Grace Shen wrote:
>
>> Dear All:
>> 
>> I am trying to run SMD for my ligand-protein complex. The purpose of the 
>> simulation is to drag the ligand out of the complex.
>> 
>> I can see the direction I want to pull the ligand visually. But I do not 
>> know how to use the VMD to get the exact pulling vector direction. The 
>> start point of the vector is fixed as the center of mass of the ligand. The 
>> end point is the carven in the receptor.
>> 
>> Thanks for help,
>> 
>> Grace
>> 
>> 
>> This email may contain confidential and privileged material for the sole 
>> use of the intended recipient.  Any review or distribution by others is 
>> strictly prohibited.  If you are not the intended recipient please contact 
>> the sender and delete all copies.
>