Re: fatal error regarding parameters

From: Adupa Vasista (adupavasista_at_gmail.com)
Date: Tue Dec 10 2019 - 11:28:22 CST

Are there any other molecules other than protein? If so, then you have to
add the parameters for that molecule too.

and while using CHARMM36, better add carb.prm separately instead of
lipid_prot_carb.prm

On Tue, Dec 10, 2019 at 10:36 PM mohammad goodarzi <mo.goodarzi82_at_gmail.com>
wrote:

> Hello,
>
> I have read a number of posts but none answered me this question.
> I am getting error as
>
> ------------- Processor 0 Exiting: Called CmiAbort ------------
>
> Reason: FATAL ERROR: DIDN'T FIND vdW PARAMETER FOR ATOM TYPE N287
>
>
> Charm++ fatal error:
>
> FATAL ERROR: DIDN'T FIND vdW PARAMETER FOR ATOM TYPE N287
>
>
> Abort trap: 6
>
>
> and my parameters are
>
> # Force-Field Parameters
> paraTypeCharmm on
> parameters ./par_all36_lipid_prot_carb.prm
> parameters ./par_all36_lipid.prm
> parameters ./par_all36_prot.prm
> parameters ./par_all36_na.prm
>
>
> I just don't know what to add more, whatever I add or remove I get the
> same error
>
> Thanks
> Mo
>

-- 
*A.VasistaM.Tech,Department Of Chemical Engineering,*
*IIT Guwahati.*

This archive was generated by hypermail 2.1.6 : Tue Dec 31 2019 - 23:21:03 CST