From: David Hardy (dhardy_at_ks.uiuc.edu)
Date: Fri Sep 07 2018 - 09:31:19 CDT
Dear Manikadan,
Obviously, this is due to running a vacuum bounded system with a barostat. The combination is not generally compatible. If you configure your simulation to output the cell basis vectors every step, you should see a substantial change in their lengths. The error is due to these lengths shrinking to the extent that it invalidates the original domain decomposition of the system.
Best regards,
Dave
-- David J. Hardy, Ph.D. Beckman Institute University of Illinois at Urbana-Champaign 405 N. Mathews Ave., Urbana, IL 61801 dhardy_at_ks.uiuc.edu, http://www.ks.uiuc.edu/~dhardy/ > On Sep 7, 2018, at 5:46 AM, Mani Kandan <manikandand5110_at_gmail.com> wrote: > > Dear all, > > My simulation box has a size of 46x502x1502 A, where vacuum has a size of 46*452*502 A . Reaming box is filled with electrolyte and my membrane. When I am running NPT simulation, I am getting the following error: > > ERROR: Constraint failure in RATTLE algorithm for atom 433303! > ERROR: Constraint failure; simulation has become unstable. > ERROR: Exiting prematurely; see error messages above. > > Same system, When I am running with NVT simulation, it is running very well. Kindly help to resolve this issue. I want to run NPT simulation. > > With Regards, > > MANIKANDAN D