From: ipsita basu (ibasu788_at_gmail.com)
Date: Tue Sep 04 2012 - 00:42:09 CDT
Sir,
I have a query regarding restarting umbrella sampling simulation of
membrane protein system.
When I start it one portion of my configuration is:
harmonic {
name lenpot
colvars distanceZ
centers 70.00
forceConstant 5.0
targetCenters 60.00
targetNumSteps 1000000
targetNumStages 100
where the distance between the two selected group is 70 which I want
to decrease to 60 in 1000000 steps. The output traj is like:
999800 6.04585123909563e+01
# step distanceZ
1000000 6.04704550193212e+01
Now when I restart the job I set the above portion as :
harmonic {
name lenpot
colvars distanceZ
centers 60.00
forceConstant 5.0
targetCenters 50.00
targetNumSteps 1000000
targetNumStages 100
But doing this the output traj file is like:
1403600 6.03582445087823e+01
1403800 6.03622946744465e+01
which means the distance is not decreasing anymore, so I omit the
option centers 60.00 and then I get the error: Error: must define the
initial centers of the restraints.
So should I set the value for centers and target centers, then what is
the difference between the two?
Or should I set off the options:
targetCenters 50.00
targetNumSteps 1000000
targetNumStages 100
Please help.
-- Ipsita Basu Research Fellow c/o : Dr. Chaitali Mukhopadhyay Rajabazar Science College 92 APC Road Kolkata - 700009