From: Jérôme Hénin (jhenin_at_ifr88.cnrs-mrs.fr)
Date: Thu Dec 22 2011 - 05:20:15 CST
Hi Giovanni,
I think your problem here is multiple time-step, which does not make
much sense when reading frames from a DCD file. I have seen NAMD react
badly to this and segfault.
Try setting fullElectFrequency to 1.
Best,
Jerome
On 21 December 2011 21:44, Giovanni Bellesia
<giovanni.bellesia_at_gmail.com> wrote:
> Hi all,
>
> I'm wondering if it's possible to calculate a collective variable (i.e., a
> dihedral calculated over 4 groups of atoms)
> from a dcd trajectory file.
> I am pasting the configuration file I am trying to use.
> What it does is ... it computes the state of the variable at the first step
> and then it stops with error message "Segmentation default"
>
> Thanks,
>
> Giovanni
>
> --------------
>
> structure ./structure.psf
> coordinates ./coords.pdb
>
> set temperature 310
> set outputname out1
>
> firsttimestep 0
>
>
> # Input
> paraTypeCharmm on
> vdwGeometricSigma yes
> parameters ./opls.prm
> temperature $temperature
>
> # Force-Field Parameters
> exclude scaled1-4
> 1-4scaling 1.0
>
> # Constant Temperature Control
> langevin on
> langevinDamping 1.0
> langevinTemp $temperature
> langevinHydrogen no
>
> # GBIS parameters
> GBIS on
> ionConcentration 0.3
> alphaCutoff 12
>
> # Nonbonded parameters
> switching on
> switchdist 12
> cutoff 13
> pairlistdist 14.5
>
> # Multistep parameters
> timestep 2.0
> rigidBonds all
> nonbondedFreq 1
> fullElectFrequency 2
> stepspercycle 10
>
> colvars on
> colvarsConfig Dihedral.in
>
> outputName $outputname
> binaryOutput no
>
> set ts 1
>
> coorfile open dcd test1.dcd
>
> # Read all frames until nonzero is returned.
> while { ![coorfile read] } {.
> firstTimestep $ts
> run 0
> incr ts 1
> }
> coorfile close
This archive was generated by hypermail 2.1.6 : Mon Dec 31 2012 - 23:21:05 CST