Hello,

I have been using NAMD for a while, but I have recently began using the
FEP module to measure free energy differences of molecules in solvents.

I am looking at the alchemical transformation of methanol --> ethane in
water.

The problem I am having is that the methanol carbon changes charge from
0.265 to 0, and therefore I need to include three carbon atoms.
I placed two carbon atoms in the pdb with the same coordinates, but with
different charges (C2, C3).

Below is the PDB and PSF for the transformation in a vacuum.

ATOM 1 C1 LIG 1 0.000 0.000 0.000 1.00 0.00 C
ATOM 2 C2 LIG 1 0.000 0.000 1.530 1.00 0.00 C
ATOM 3 H1 LIG 1 1.026 0.000 -0.373 1.00 0.00 H
ATOM 4 H2 LIG 1 -0.512 0.888 -0.373 1.00 0.00 H
ATOM 5 H3 LIG 1 -0.513 -0.888 -0.373 1.00 0.00 H
ATOM 6 H4 LIG 1 0.513 0.888 1.903 1.00 0.00 H
ATOM 7 H5 LIG 1 0.512 -0.888 1.903 1.00 0.00 H
ATOM 8 O1 LIG 1 -1.344 0.000 2.019 1.00 0.00 O
ATOM 9 H6 LIG 1 -1.677 0.019 2.919 1.00 0.00 H
ATOM 10 C3 LIG 1 0.000 0.000 1.530 1.00 0.00 H
ATOM 11 H7 LIG 1 -1.025 0.000 1.903 1.00 0.00 H
END

       11 !NATOM
        1 O1 1 LIG C1 CR 0.000000 12.0110 0
        2 O1 1 LIG C2 CR 0.265000 12.0110 0
        3 O1 1 LIG H1 HCMM 0.000000 1.0079 0
        4 O1 1 LIG H2 HCMM 0.000000 1.0079 0
        5 O1 1 LIG H3 HCMM 0.000000 1.0079 0
        6 O1 1 LIG H4 HCMM 0.000000 1.0079 0
        7 O1 1 LIG H5 HCMM 0.000000 1.0079 0
        8 O1 1 LIG O1 OR -0.700000 15.9994 0
        9 O1 1 LIG H6 HOR 0.435000 1.0079 0
      10 O1 1 LIG C3 CR 0.000000 12.0110 0
      11 O1 1 LIG H7 HCMM 0.000000 1.0079 0

       12 !NBOND: bonds
        1 2 2 6 2 7 2 8
        3 1 4 1 5 1 8 9
       10 1 10 6 10 7 10 11

When I run the simulation I receive an error of bad hydrogen group size
on atom 2, although atom 2 is the methanol carbon and is connected to
1C, H4, H5 and O1.

Please advise, I can't see anything wrong with the hydrogen counts.

Many thanks in advance,
John Baker (PhD candidate, University of Nottingham)

This message and any attachment are intended solely for the addressee and may contain confidential information. If you have received this message in error, please send it back to me, and immediately delete it. Please do not use, copy or disclose the information contained in this message or in any attachment. Any views or opinions expressed by the author of this email do not necessarily reflect the views of the University of Nottingham.

This message has been checked for viruses but the contents of an attachment
may still contain software viruses which could damage your computer system:
you are advised to perform your own checks. Email communications with the
University of Nottingham may be monitored as permitted by UK legislation.

This archive was generated by hypermail 2.1.6 : Mon Dec 31 2012 - 23:21:03 CST