From: JC Gumbart (gumbart_at_ks.uiuc.edu)
Date: Thu Apr 28 2011 - 18:41:17 CDT
I just ran into an issue, something that worked in 2.7 but no longer works in 2.8. Specifically, using a harmonic to restrain an orientation. The error is this:
colvars: ----------------------------------------------------------------------
colvars: Collective variables initialized, 9 in total.
colvars: ----------------------------------------------------------------------
colvars: Initializing a new "harmonic" instance.
colvars: # name = "harmonic1" [default]
colvars: # colvars = { Omega }
colvars: # forceConstant = 500
colvars: # centers = { ( 1 , 0 , 0 , 0 ) }
colvars: Trying to use a colvar value with type "4-dimensional unit vector" as one of type "scalar number".
colvars: If this error message is unclear, try recompiling with -DCOLVARS_DEBUG.
FATAL ERROR: Error in the collective variables module: exiting.
------------- Processor 0 Exiting: Called CmiAbort ------------
Reason: FATAL ERROR: Error in the collective variables module: exiting.
and the relevant part of my input is this:
colvar {
name Omega
orientation {
atoms {
atomnumbers { ... }
}
refPositionsFile ../reference-protein.pdb
refPositionsCol B
}
}
harmonic {
colvars Omega
forceConstant 500.0
centers ( 1.0, 0.0, 0.0, 0.0 )
}
Any idea what's up?
Thanks,
JC