From: Axel Kohlmeyer (akohlmey_at_gmail.com)
Date: Wed Mar 02 2011 - 11:39:39 CST
On Wed, Mar 2, 2011 at 11:56 AM, Francesco Pietra <chiendarret_at_gmail.com> wrote:
>
> (2) What about the dielectric constant for such an ensemble, spanning
> from 1 for the protein (and the lipid ?) and ca 80 for TIP3? Specific,
> authoritative tutorial, such as
> <http://mccammon.ucsd.edu/~rlaw/ctbp_workshop_rlaw.htm> do not mention
> dielectric.
i am wondering why people come up with this thing all the time.
it doesn't make any sense at all, if you really thing about it.
a choice of 1 (vacuum) is the proper choice for an all atom simulation
with explicit solvent. the fact that you have a higher dielectric constant
in water, for example, is a _result_ of the calculation (the static DEC
is a measure for the response to local polarization). you only need
to set the dielectric constant for an _implicit_ model, where you
approximate the screening of coulomb interactions by a continuum
model.
for more details i suggest having a look at text books on the
subject, e.g. hansen, macdonald, theory of simple liquids.
cheers,
axel.
> Thanks for advice
>
> francesco pietra
>
>
-- Dr. Axel Kohlmeyer akohlmey_at_gmail.com http://goo.gl/1wk0 Institute for Computational Molecular Science Temple University, Philadelphia PA, USA.
This archive was generated by hypermail 2.1.6 : Mon Dec 31 2012 - 23:19:52 CST