From: Gianluca Interlandi (gianluca_at_u.washington.edu)
Date: Thu Dec 02 2010 - 11:30:02 CST
Because the spring contracts again and due to Hook's law the force goes 
down.
Gianluca
On Thu, 2 Dec 2010, B. Nandy wrote:
> Dear NAMD users,
>
> I have another question.  In SMD why force drops to zero at large
> separation even though the  pulling spring is in action.
>
> Thanking you.
> Bidisha
> IISC Bangalore
> India
>
> -- 
> This message has been scanned for viruses and
> dangerous content by MailScanner, and is
> believed to be clean.
>
>
-----------------------------------------------------
Gianluca Interlandi, PhD gianluca_at_u.washington.edu
                     +1 (206) 685 4435
                     http://artemide.bioeng.washington.edu/
Postdoc at the Department of Bioengineering
at the University of Washington, Seattle WA U.S.A.
-----------------------------------------------------