From: Leonardo Sepulveda Durán (leonardosepulveda_at_gmail.com)
Date: Wed Jun 15 2005 - 20:55:29 CDT
Hello everybody
I was trying to do a NVE simulation in NAMD. I used imput coordinate
and velocity files from a NVT simulation which was equilibrated at
desired temperature (498 K)
Looking at TOTE3, it is obvious my system's energy underwent a slow
drift (from -20235 to -20225 in 250 ps ). The .conf I used is below:
structure                ./ubq-wb.psf
coordinates            ./ubq-min.coor
# For Continuing a run, otherwise comment all but firsttimestep
set inputname         ubq-heat
binCoordinates        $inputname.coor   ;# coordinates for last run (binary))
binVelocities	        $inputname.vel     ;# velocities for last run (binary)
extendedSystem     $inputname.xsc    ;# Cell dymentions for last run
firsttimestep            41500                  ;# Last step previous run
numsteps                125000                ;# run stops when this
step is reached
# Force-Field Parameters
paraTypeCharmm	   on
parameters         	/home/RPMs/NAMD/toppar/par_all22_prot.inp 
exclude             	  scaled1-4
1-4scaling          	 1.0
switching                on
switchdist          	 10.;         # cutoff-2
cutoff                      12.;         # may be 10 with PME
pairlistdist        	   14.;		# cutoff+2
margin               0.498;
# Integrator Parameters
timestep            	 2.0;		# 2fs/step
rigidBonds          	 all;		# needed for 2fs steps (SHAKE)
nonbondedFreq          1
fullElectFrequency  	2  
stepspercycle       	10
outputPairlists         1000
# Periodic Boundary Conditions
cellBasisVector1    	50.68    0.   0.
cellBasisVector2     	0.   52.37   0.
cellBasisVector3     	0.    0.   56.27
cellOrigin          	30.85  29.14  17.90
wrapAll             	on
# PME (for full-system periodic electrostatics)
PME                 	yes
PMEGridSizeX        	 54
PMEGridSizeY        	54
PMEGridSizeZ        	 60
# Output
outputName          	ubq-eq
binaryOutput             yes; 
restartfreq         	     500;		# 500steps = every 1ps
dcdfreq             	     500
xstFreq             	     500
outputEnergies      	 100
outputPressure      	 100
outputTiming		 1000
I was wondering if someone can give me an advice about how to get my
simulations conservative. I am confused about some concepts and
parameters...for example, in the manual,  stepspercycle is explained
as  the number of timesteps beetween atom
reasignments; I thought it was refering to pairlist reasignment, but
later "pairlistpercycle" is defined as the number of times  pairlists
are regenerated in one cycle...so if I have
stepspercycle    = 20
pairlistpercycle  = 2
is the same as using
stepspercycle    = 10
pairlistpercycle  = 1    ?????
I really dont understand the difference. Also I put outputPairlists 
because it sound useful to avoid atoms to pass the pairlist boundary,
but i am not sure if only give the pairlists violations. So I would
like to ask if someone have done NVE simulations succesfully, and what
parameters can be adecuate to do it.
Thanks 
Leonardo
PD: I attach a .pdf with temperature and energy from my simulation.
This archive was generated by hypermail 2.1.6 : Wed Feb 29 2012 - 15:39:34 CST