From: Brian Bennion (brian_at_youkai.llnl.gov)
Date: Wed Jul 21 2004 - 17:29:51 CDT
Hi Julie,
The error may effect the final structure.  The cause of the error in this
case is a small box dimensions relative to your nonbonded cutoffs.
Check the list archive for previous discussions on this topic.
Regards
Brian
On Wed, 21 Jul 2004, Stern, Julie wrote:
> Hello,
>     I'm getting the error messages:
> "Warning:  Bad global exclusion count, possible error!
> Warning:  Increasing cutoff during minimization may avoid this."
> for the first 142 steps of my energy minimization.  The warnings
> then disappear.  Does the fact that the warning goes away
> mean that everything is okay or did some errors get propagated
> in my calculations? Can I trust my results?  Thanks.
>
> Sincerely,
> Julie Stern
>
*****************************************************************
**Brian Bennion, Ph.D.                                         **
**Computational and Systems Biology Division                   **
**Biology and Biotechnology Research Program                   **
**Lawrence Livermore National Laboratory                       **
**P.O. Box 808, L-448    bennion1_at_llnl.gov                     **
**7000 East Avenue       phone: (925) 422-5722                 **
**Livermore, CA  94550   fax:   (925) 424-6605                 **
*****************************************************************
This archive was generated by hypermail 2.1.6 : Wed Feb 29 2012 - 15:38:48 CST