From: Ekta Khurana (ekta_at_athanor.cmm.upenn.edu)
Date: Tue May 25 2004 - 16:22:00 CDT
HI everyone,
       I am running constant surface tension simulation with a constant 
normal pressure.If I use NAMD 2.5 I get the error
FATAL ERROR: Periodic cell has become too small for original patch grid!
Possible solutions are to restart from a recent checkpoint,
increase margin, or disable useFlexibleCell for liquid simulation.
     Sometimes I am able to fix the problem using the suggested 
solutions BUT the same system runs fine with the earlier version of NAMD. The same 
question has been asked on the list earlier also but there was no clear 
answer.Can someone explain this error a little bit in detail.And also why 
it appears only with the newer version.
Thankyou,
Ekta
This archive was generated by hypermail 2.1.6 : Wed Feb 29 2012 - 15:38:41 CST