From: Tim Isgro (timisgro_at_ks.uiuc.edu)
Date: Thu Mar 25 2004 - 11:11:07 CST
This should do it:
## Heating Process
reassignFreq    200
reassignTemp    300
reassignIncr    10
reassignHold    340
ReassignFreq gives the number of timesteps after which the temperature is
changed.  ReassignTemp gives the initial temp.  ReassignIncr gives the
amount by which to increase T every (200) steps.  ReassignHold gives the
final T, and will keep the run at that T if you want to run for more than
1000 steps.
Tim
On Thu, 25 Mar 2004, mashaojie wrote:
> Dear Sir:
>    I don't know how to write configure file on use temperature anneling or temperature increase gradually.Could  you give me a example configure file.
>   for example, simulation from 300K  to 340K while run 1000.
>   thank you very much
>
>
This archive was generated by hypermail 2.1.6 : Wed Feb 29 2012 - 15:38:31 CST