From: Brian Bennion (brian_at_youkai.llnl.gov)
Date: Thu Feb 26 2004 - 15:29:38 CST
The command is
firsttimestep XXX
xxx would be your last step from the previous simulation.
comment out the number of steps and use the command
run YYYYY
at the end of your namd config.
Brian
On Thu, 26 Feb 2004, Sichun Yang wrote:
>
> Dear Namd users,
>
> I restart the simulations from the previous run.
> However, the timestep starts to count from 0 again in the new output file.
> I am wondering whethere there is an option to change it. Thanks,
>
*****************************************************************
**Brian Bennion, Ph.D. **
**Computational and Systems Biology Division **
**Biology and Biotechnology Research Program **
**Lawrence Livermore National Laboratory **
**P.O. Box 808, L-448 bennion1_at_llnl.gov **
**7000 East Avenue phone: (925) 422-5722 **
**Livermore, CA 94550 fax: (925) 424-6605 **
*****************************************************************
This archive was generated by hypermail 2.1.6 : Wed Feb 29 2012 - 15:38:27 CST