Re: Umbrella sampling colvars DistanceZ deviates a lot

From: Sourav Ray (souravray90_at_gmail.com)
Date: Tue Sep 13 2016 - 15:22:47 CDT

Hello

If I may add, it is better to keep the box size large (to accommodate the
variation in colvar) and specify an upper boundary (in case it can be
determined) to get reasonable results, else the periodic conditions will
result in large fluctuations in the output generated.

Regards
Sourav

On Wed, Sep 14, 2016 at 1:46 AM, Giacomo Fiorin <giacomo.fiorin_at_gmail.com>
wrote:

> Hi Kevin, the wrapping is only done in the file, not in the memory during
> a run. Thus, any wrapping issue would only arise when the restart file is
> read by the next run.
>
> On Tue, Sep 13, 2016 at 1:27 PM, Tabris Chun Chan <
> cchan2242-c_at_my.cityu.edu.hk> wrote:
>
>> Hi Fiorin, thank you for the hints. However, I am wondering if it is the
>> case, shouldn't colvars meaure the value after NAMD unwrapping the restart
>> coordinates? If it is really reading a wrapped value, what will happen when
>> it couples a wrapped value to the window center during a unwrapped run?
>> Hard to imagine.
>>
>> Many thanks!
>>
>> Regards,
>> Kevin
>>
>>
>> On 14 Sep 2016, 00:24 +0800, Giacomo Fiorin <giacomo.fiorin_at_gmail.com>,
>> wrote:
>>
>> Hello Kevin, try looking into possible PBC wrapping issues. Coordinates
>> are internally unwrapped during a run, but get wrapped when an output file
>> (such as a restart is written) and this will affect the next run.
>>
>>
>>
>> On Tue, Sep 13, 2016 at 12:19 PM, Kevin C Chan <
>> cchan2242-c_at_my.cityu.edu.hk> wrote:
>>
>>> Dear Users,
>>>
>>> I am doing umbrella sampling in NAMD with the colvars function. I have
>>> specify a colvars file like this:
>>> colvarsTrajFrequency 20
>>> colvarsRestartFrequency 1000
>>>
>>> colvar {
>>> name ProjectionZ
>>>
>>> width 1.0
>>>
>>> distanceZ {
>>> main {
>>> atomsFile ../main.pdb
>>> atomsCol B
>>> atomsColValue 1.0
>>> }
>>> ref {
>>> atomsFile ../ref.pdb
>>> atomsCol B
>>> atomsColValue 1.0
>>> }
>>> forceNoPBC yes
>>> }
>>> }
>>>
>>> harmonic {
>>> colvars ProjectionZ
>>> centers 59.5
>>> forceConstant 4.0
>>> }
>>>
>>> Pretty standard. The first three lines of colvars.traj reads:
>>> 0 5.96855721722479e+01
>>> 20 5.96916027979287e+01
>>> 40 5.96942978400560e+01
>>> Pretty close. The last three lines of colvars.traj reads:
>>> 499940 5.91646234042935e+01
>>> 499960 5.91735242021637e+01
>>> 499980 5.91815463732824e+01
>>> Also close. Good. However, strange things happen when I restart the
>>> simulation over and over again from restart.coor, restart.vel and
>>> restart.xsc files.
>>> After a few times (~70) of restarts. While the last three lines of
>>> another colvars.traj reads:
>>> 606960 5.95480754008586e+01
>>> 606980 5.95456901525873e+01
>>> 607000 5.95617980942163e+01
>>> The first three lines of the next colvars.traj reads:
>>> 0 6.33546567861433e+01
>>> 20 6.33540970478523e+01
>>> 40 6.33519859940328e+01
>>> which was pretty far away from what I want. Then I can see the colvars
>>> shifting the value towards 5.95. Then for the next colvars.traj:
>>> 0 4.86674663226018e+01
>>> 20 4.86540561800189e+01
>>> 40 4.86566065988872e+01
>>>
>>> There seems to have something wrong with restarting simulations with
>>> colvars turned on. Anyone has experience on this?
>>>
>>> Thanks in advance.
>>>
>>> Regards,
>>> Kevin
>>> City University of Hong Kong
>>> ukevi_at_gmx.hk
>>>
>>
>>
>>
>> --
>> Giacomo Fiorin
>> Associate Professor of Research
>> Institute for Computational Molecular Science (ICMS)
>> College of Science and Technology, Temple University
>> 1925 North 12th Street (035-07), Room 704D
>> Philadelphia, PA 19122-1801
>> Phone: +1-215-204-4213
>>
>> Scholar: http://goo.gl/Q3TBQU
>> Personal: http://giacomofiorin.github.io/
>> Lab page: https://icms.cst.temple.edu/members.html
>>
>> *"As computer programmers we have a responsibility to make sure that we
>> run the computers instead of the computers running us."* - Steve
>> Oualline
>>
>>
>>
>
>
> --
> Giacomo Fiorin
> Associate Professor of Research
> Institute for Computational Molecular Science (ICMS)
> College of Science and Technology, Temple University
> 1925 North 12th Street (035-07), Room 704D
> Philadelphia, PA 19122-1801
> Phone: +1-215-204-4213
>
> Scholar: http://goo.gl/Q3TBQU
> Personal: http://giacomofiorin.github.io/
> Lab page: https://icms.cst.temple.edu/members.html
>
> *"As computer programmers we have a responsibility to make sure that we
> run the computers instead of the computers running us."* - Steve Oualline
>
>
>

This archive was generated by hypermail 2.1.6 : Sun Dec 31 2017 - 23:20:43 CST