From: Bonnie Merchant (merchantb_at_duq.edu)
Date: Mon Jun 29 2009 - 11:00:07 CDT
Jerome & Giacomo-
Thanks so much! I'm glad it's a simple fix! :)
There is/was no particular reason I was using the oneSiteSystemForce,
thanks for the heads up.
Best Regards,
Bonnie Merchant
On Fri, June 26, 2009 3:26 pm, Jerome Henin wrote:
Hi Bonnie,
You need to set the restartName parameter in your NAMD input.
Also, is there a particular reason for you to use oneSiteSystemForce?
If you are unsure, you probably don't need it.
Jerome
On Fri, Jun 26, 2009 at 2:41 PM, Bonnie Merchant<merchantb_at_duq.edu> wrote:
> Hello All,
>
> I might be missing something quite simple, but I'm not sure why I keep
> getting this error in an Colvars/ABF simulation in NAMD 2.7b1:
>
> colvars: Error: undefined output or restart file.
> colvars: If this error message is unclear, try recompile with
> -DCOLVARS_DEBUG.
> FATAL ERROR: Error in the collective variables module: exiting.
>
> Do I need to define an output name within the colvarsConfig file (a
> separate name from the one in the NAMD conf file)?
>
> I tried defining "outputName" within the colvarsConfig file, but it then
> reports this error:
>
> Colvars: Error: keyword "outputname" is not supported, or not recognized
> in this context.
>
> My Colvars Config is as follows:
>
> colvarsTrajFrequency 10
> colvarsRestartFrequency 10000
> analysis on
>
> colvar {
> name d
> width 0.2
> lowerBoundary 5.0
> upperBoundary 15.0
> lowerWallConstant 10.0
> upperWallConstant 10.0
>
> distance {
> group1 {atomNumbersRange 8210-8231}
> group2 {atomNumbers 8232 8233 8234}
> oneSiteSystemForce yes
> }
> }
> abf {
> colvars d
> fullSamples 500
> outputFreq 500
> applyBias yes
> }
>
>
> Any advice would be much appreciated. Thanks in advance,
>
> Bonnie
>
>
This archive was generated by hypermail 2.1.6 : Wed Feb 29 2012 - 15:52:58 CST