From: Tanooj Shah (shaht2_at_rpi.edu)
Date: Fri Oct 30 2020 - 21:52:19 CDT
Hello,
I wanted to ask if it is possible to run an NPT simulation for a certain 
number of frames and then subsequently an NVT simulation starting from 
the coordinates at the end of the NPT part. I believe it is possible to 
do this in separate config files but I am getting some inconsistent 
results which is why I wanted to ask if it possible to modify the config 
file to perform both (similar to how in LAMMPS you would write a fix, 
unfix and then another fix command).
Specifically, I am trying to run a simulation of just a water box. It 
didn't seem clear how to create a box of water purely from scratch so I 
did it in a roundabout way - I wrote a pgn script to create a sodium 
ion, added a solvation box around it, and then wrote another pgn script 
to delete the sodium ion. Not sure if there is a cleaner way to fill a 
simulation box with water and nothing else.
I initially ran an NPT simulation at T=300K, 
LangevinPistonTarget=1.01325 bar (the default) and averaged the density 
of the water in the box over all frames and got a result of around 0.94 
g/cm3, which is lower than the expected water density for the TIP3P 
model (0.98 g/cm3). I increased the LangevinPistonTarget until I was 
able to get a stable density of 0.98 g/cm3 (this was at a 
LangevinPistonTarget of around 875 atm, I had to try multiple different 
values to get the "correct" density).
I used the last frame of the .coor file as an input pdb file (and 
generated a corresponding psf file) to an input to an NVT simulation 
with a slightly reduced cell size (to match the compression from the NPT 
run). However at the end of the NVT run I am still getting a density too 
low - around 0.92 g/cm3. However I suspect this might be because the new 
cell size is not exact.
I have two questions mainly - one, is is it possible to run an NPT and 
an NVT simulation in the same config file? And the second is more 
general and not sure if it is appropriate to post here - why am I 
getting a simulation lower than 0.98 g/cm3 for water at STP? Is this 
happening because when I deleted the sodium ion that created a void? Is 
there a way to create a solvation box for "no" atoms so the entire 
simulation box is uniformly filled with water?
Thank you if you took the time to read this entire message.
Best,
-- Tanooj Shah Materials Science Department Rensselaer Polytechnic Institute
This archive was generated by hypermail 2.1.6 : Fri Dec 31 2021 - 23:17:10 CST