From: Ali Mehdizadeh Rahimi (mehdizadehrahimi.a_at_husky.neu.edu)
Date: Wed Sep 12 2018 - 19:34:37 CDT
Dear All,
The problem that I’m interested in is to charge two naked Lennard-Jones
particles to opposite unit charges (create a dipole), starting from zero
charge to the two atom’s final charge (-1 and +1). I want to calculate the
charging free energies of the dipole as I change the distance between the
two atoms (and ultimately obtain a landscape of energy as a function of the
distance between the two atoms to assess the accuracy of a continuum theory
that I’m working on).
I went through the FEP tutorial for charging a spherical sodium ion.
The change that I made to the setup.pgn was to add another sodium segment:
segment SOD1 {
residue 1 SOD
}
segment SOD2 {
residue 2 SOD
}
and wrote the outputs to setup.pdb and setup.psf files.
I modified the resulting psf file:
…
4 !NTITLE
REMARKS original generated structure x-plor psf file
REMARKS topology ../common/top_all22_prot.inp
REMARKS segment SOD1 { first NONE; last NONE; auto angles dihedrals }
REMARKS segment SOD2 { first NONE; last NONE; auto angles dihedrals }
2 !NATOM
1 SOD1 1 SOD SOD SOD -1.000000 22.9898 0
2 SOD2 2 SOD SOD SOD 1.000000 22.9898 0
….
and the pdb file (e.g. for when the distance between the two oppositely
charged atoms, d, is 6 A):
REMARK original generated coordinate pdb file
ATOM 1 SOD SOD 1 -3.000 0.000 0.000 -1.00 0.00 SOD1
NA
ATOM 2 SOD SOD 2 3.000 0.000 0.000 -1.00 0.00 SOD2
NA
END
and then solvated the dipole in a water box using solvate plugin of VMD and
modified solvate.pdb:
CRYST1 46.000 46.000 46.000 90.00 90.00 90.00 P 1 1
ATOM 1 SOD SOD S 1 -3.000 0.000 0.000 1.00 1.00 SOD1
NA
ATOM 2 SOD SOD S 2 3.000 0.000 0.000 1.00 1.00 SOD2
NA
ATOM 3 OH2 TIP3W 5 -19.332 -9.918 -4.096 1.00 0.00 WT1
O
ATOM 4 H1 TIP3W 5 -19.776 -9.549 -4.899 1.00 0.00 WT1
H
ATOM 5 H2 TIP3W 5 -19.908 -9.621 -3.373 1.00 0.00 WT1
H
….
….
and saved as solvate.fep.
Finally equilibrated the system and ran forward and backward simulations.
What would be the right expression to estimate the error due to the
size-dependence of the energy to the system in my problem since the box is
already charge-neutral?
Thanks a lot for taking the time,
Ali
This archive was generated by hypermail 2.1.6 : Mon Dec 31 2018 - 23:21:23 CST