From: Goedde, Chris (CGOEDDE_at_depaul.edu)
Date: Wed Feb 01 2017 - 14:45:02 CST
On Feb 1, 2017, at 12:31 PM, Darya Fadavi <daryafadavi_at_berkeley.edu> wrote:
>
> Hello,
>
> I'm trying to calculate energy plots (VDW, Elec, Nonbond) using the NAMD Energy extension. I've specified the parameter file I used but when I try to run it, I get the error that "namd2.exe has stopped working". I'm working on Windows, and I downloaded and extracted the entire zip file for namd, so I don't think I'm missing any files.
>
> I then looked to the temp log file created in the current directory to see what the fatal error was and it says "FATAL ERROR: UNABLE TO OPEN .psf FILE C:UsersDarya FadaviDocumentsMofrad_Lab mdSUN projectMouseSun1 dxt templateWith KRun1mousesun1_ionized.psf". I'm not sure why it wasn't able to open the psf file. I've loaded it in vmd and opened the dcd file on top of it at stride 10.
I had trouble with the unix version of namd choking on path names that were longer than about 135 characters. This might be a similar issue. You could try renaming or moving the file so the path length is shorter and seeing if that fixes things.
Chris Goedde
This archive was generated by hypermail 2.1.6 : Mon Dec 31 2018 - 23:20:04 CST