From: Jeff Comer (jeffcomer_at_gmail.com)
Date: Fri Dec 05 2014 - 15:00:44 CST
Hi,
I'm having some trouble using an "angle" colvar with "centerReference
on". I think this used to work.
As a test, I define a "distance" colvar by:
colvar {
name distFixed
distance {
group1 {
atomNumbers 1
centerReference on
refPositions (3,0,0)
}
group2 {
atomNumbers 68
centerReference on
refPositions (0,0,0)
}
}
}
I expect that this distance is always 3.0, and indeed it is.
However, for "angle" colvar, it doesn't seem to work like this. I
would expect the following to always give 90, but it does not.
colvar {
name phi6
angle {
group1 {
atomNumbers 1
centerReference on
refPositions (1,0,0)
}
group2 {
atomNumbers 34
centerReference on
refPositions (0,0,0)
}
group3 {
atomNumbers 68
centerReference on
refPositions (0,0,1)
}
}
}
Is this a bug, or is there something that I'm missing?
Thanks,
Jeff
–––––––––––––––––––––––––––––––––––———————
Jeffrey Comer, PhD
Assistant Professor
Institute of Computational Comparative Medicine
Nanotechnology Innovation Center of Kansas State
Kansas State University
Office: P-213 Mosier Hall
Phone: 785-532-6311