From: Norman Geist (norman.geist_at_uni-greifswald.de)
Date: Tue Jun 10 2014 - 07:26:58 CDT
As long as there’s no constant linear momentum, I guess there’s no problem, simply Brownian motion. Otherwise it may be effects like “center of mass drift” due long range electrostatics (PME) which represents a high center of mass motion. This can be controlled by the namd options “zeromomentum” and “commotion”.
Norman Geist.
Von: Akshay Bhatnagar [mailto:akshaybhatnagar2790_at_gmail.com]
Gesendet: Dienstag, 10. Juni 2014 14:19
An: Norman Geist
Betreff: Re: namd-l: Reg: movement of protein outside box
Thank you very much for your suggestions and kind help
But, in my system, the amino acid i am simulating is there at the center position already which i checked through the command "measure center $protein" and so is the water box. so, should i use the “pbc wrap –all –compound res –center com –centersel protein”? , Also I wanted to ask that is this diffusion a normal process after equilibration or is it due to bad system or bad parameters in the configuration file. Actually what could be the reason for diffusion if the system is already at the origin position.
Thanking you
With Regards
Akshay Bhatnagar
PhD Student
BITS Pilani Hyderabad Campus
On Tue, Jun 10, 2014 at 1:17 PM, Norman Geist <norman.geist_at_uni-greifswald.de> wrote:
Von: owner-namd-l_at_ks.uiuc.edu [mailto:owner-namd-l_at_ks.uiuc.edu] Im Auftrag von Akshay Bhatnagar
Gesendet: Dienstag, 10. Juni 2014 03:47
An: namd-l_at_ks.uiuc.edu
Betreff: namd-l: Reg: movement of protein outside box
Hello everyone
I have performed a 10 ns equilibration to simulate a amino acid in a 30 A water box, but after the equilibration the amino acid has moved to the corner of the box. can anyone explain me the reason?
Diffusion. If you wan’t to have it in the middle of the box, see in VMD “pbc wrap –all –compound res –center com –centersel protein”. Please notice that the
Center of the box can be everywhere you want.
Also can anyone tell me the exact difference between equilibration and production run? If I use pressure control parameter in equilibration then is it equivalent to production run?
During equilibration you usually have: restraints, temperature control, pressure control … (see NVT,NPT)
During production run you usually have no external controls of your simulation. (see NVE)
Thank you very much
With Regards
Akshay Bhatnagar
PhD Student
BITS Pilani Hyderabad Campus
_____
Diese E-Mail ist frei von Viren und Malware, denn der avast! Antivirus <http://www.avast.com/> Schutz ist aktiv.
--- Diese E-Mail ist frei von Viren und Malware, denn der avast! Antivirus Schutz ist aktiv. http://www.avast.com
This archive was generated by hypermail 2.1.6 : Thu Dec 31 2015 - 23:20:51 CST