From: mjyang (mjyang_at_hku.hk)
Date: Sun Oct 17 2010 - 02:03:31 CDT
Dear NAMD users,
   I performed a simulation of a protein + TIP3 water system at 600K. But after 2 ns production run under NPT ensemble,  the volume of solvation box expanded by more than 1000 times and the mass density reduced from 1.05909 g/cm^3 to 0.000607189 g/cm^3.  I am not sure whether this phenomenan is caused by NPT ensemble at hight temperature or any other factors.
The following three NPT schemes were tested and the expansion occured in all cases:
scheme a: temperature control 1 and pressure control 1
scheme b: temperature control 1 and pressure control 2
scheme c: temperature control 2 and pressure control 2
Could someone please tell me how to fix this problem?
------------------------
Temperature control:
1.
     langevin            on    ;# do langevin dynamics
    langevinDamping     5     ;# damping coefficient (gamma) of 5/ps
    langevinTemp        $temperature
    langevinHydrogen    no    ;# don't couple langevin bath to hydrogens
2.
    tcouple on
    tcoupletemp $temperature
Pressure control:
1.
   useGroupPressure      yes ;# needed for 2fs steps
    useFlexibleCell       no  ;# no for water box, yes for membrane
    useConstantArea       no  ;# no for water box, yes for membrane
    berendsenpressure on
    berendsenpressuretarget 1.01325
    berendsenpressurecompressibility 4.57e-5
    berendsenpressurerelaxationtime 100
    berendsenpressurefreq 10
2.
    useGroupPressure      yes ;# needed for 2fs steps
    useFlexibleCell       no  ;# no for water box, yes for membrane
    useConstantArea       no  ;# no for water box, yes for membrane
    langevinPiston        on
    langevinPistonTarget  1.01325 ;#  in bar -> 1 atm
    langevinPistonPeriod  100.
    langevinPistonDecay   50.
    langevinPistonTemp    $temperature
    SurfaceTensionTarget  0.0     ;
-----------------------------
Thanks for the time.
Mingjun
This archive was generated by hypermail 2.1.6 : Wed Feb 29 2012 - 15:54:37 CST