Re: FATAL ERROR: Periodic cell has become too small for original patch grid!

From: Jerome Henin (jhenin_at_cmm.chem.upenn.edu)
Date: Wed Apr 22 2009 - 10:11:15 CDT

Hi Dimitry,

> Reason: FATAL ERROR: Periodic cell has become too small for original patch grid!
> Possible solutions are to restart from a recent checkpoint,
> increase margin, or disable useFlexibleCell for liquid simulation.
>
> Any suggestions? Thanks. I appreciate your time

Well, completely off the top of my head, I would say that possible
solutions are to restart from a recent checkpoint, increase the
margin, or disable useFlexibleCell for a liquid simulation.

Cheers,
Jerome

PS: Of course, Peter's reply is also worth checking out.