Dear all,
I used the rbcg-2009.par and rbcg-2009.par to simulate my system
including 300 AAs and 5000 TIP3 .
When the timestep was great than 10 (fs/step), my system was broken and
the error message(the atom moving
too fast ......) was appeared. Then I changed the timestep value and the
value was equal to 5. And my system is still
running and stable. Anyone could tell me how the limit of timestep with
rbcg-2009 parameters ?
Thanks