From: Kevin C Chan (cchan2242-c_at_my.cityu.edu.hk)
Date: Tue Sep 13 2016 - 11:19:08 CDT
Dear Users,
I am doing umbrella sampling in NAMD with the colvars function. I have
specify a colvars file like this:
colvarsTrajFrequency     20
colvarsRestartFrequency  1000
colvar {
   name ProjectionZ
   width 1.0
   distanceZ {
      main {
        atomsFile ../main.pdb
        atomsCol B
        atomsColValue 1.0
      }
      ref {
        atomsFile ../ref.pdb
        atomsCol B
        atomsColValue 1.0
      }
      forceNoPBC yes
   }
}
harmonic {
  colvars ProjectionZ
  centers 59.5
  forceConstant 4.0
}
Pretty standard. The first three lines of colvars.traj reads:
           0    5.96855721722479e+01
          20    5.96916027979287e+01
          40    5.96942978400560e+01
Pretty close. The last three lines of colvars.traj reads:
      499940    5.91646234042935e+01
      499960    5.91735242021637e+01
      499980    5.91815463732824e+01
Also close. Good. However, strange things happen when I restart the
simulation over and over again from restart.coor, restart.vel and
restart.xsc files.
After a few times (~70) of restarts. While the last three lines of
another colvars.traj
reads:
      606960    5.95480754008586e+01
      606980    5.95456901525873e+01
      607000    5.95617980942163e+01
The first three lines of the next colvars.traj reads:
           0    6.33546567861433e+01
          20    6.33540970478523e+01
          40    6.33519859940328e+01
which was pretty far away from what I want. Then I can see the colvars
shifting the value towards 5.95. Then for the next colvars.traj:
           0    4.86674663226018e+01
          20    4.86540561800189e+01
          40    4.86566065988872e+01
There seems to have something wrong with restarting simulations with
colvars turned on. Anyone has experience on this?
Thanks in advance.
Regards,
Kevin
City University of Hong Kong
ukevi_at_gmx.hk
This archive was generated by hypermail 2.1.6 : Tue Dec 27 2016 - 23:22:28 CST