Re: FATAL ERROR: DIDN'T FIND vdW PARAMETER FOR ATOM TYPE OC2D2

From: Jeff Comer (jeffcomer_at_gmail.com)
Date: Wed Mar 18 2015 - 17:35:39 CDT

Hi,

OC2D2 is a carbohydrate type. You probably need "parameters
par_all36_carb.prm" in your NAMD config file.

Jeff

–––––––––––––––––––––––––––––––––––———————
Jeffrey Comer, PhD
Assistant Professor
Institute of Computational Comparative Medicine
Nanotechnology Innovation Center of Kansas State
Kansas State University
Office: P-213 Mosier Hall
Phone: 785-532-6311

On Wed, Mar 18, 2015 at 4:47 PM, Sadegh Faramarzi Ganjabad
<safaramarziganjabad_at_mix.wvu.edu> wrote:
> Hello
>
> I'm having an issue with NAMD configuration file, similar to link below,
>
> http://www.ks.uiuc.edu/Research/namd/mailing_list/namd-l.2012-2013/3527.html
>
> although I put par_all36_cgenff.prm and par_all36_lipid.prm before the
> streams files (toppar_all36_lipid_detergent.str and
> toppar_water_ions_fixed.str). Does anybody know what
> the problem is?
>
> Thanks
> Sadegh

This archive was generated by hypermail 2.1.6 : Tue Dec 27 2016 - 23:21:00 CST