Re: Kb, Ktheta values for TIP3P water model

From: Hadi (dinpajooh_at_gmail.com)
Date: Tue Aug 05 2014 - 14:10:14 CDT

Kenno,

In general, I think it is fair to say that unlike MC simulations, the rigid
models in MD simulations are only slightly flexible considering the
algorithm, rigid tolerance, time step, etc. that will be used. I have
plotted the histogram of bond length for a given model with appropriate
parameters and observed that the distribution of bond length has some small
deviations from a delta function.

Hadi

On Tue, Aug 5, 2014 at 11:41 AM, Kenno Vanommeslaeghe <
kvanomme_at_rx.umaryland.edu> wrote:

> That doesn't mean the model wouldn't be rigid, just that the temperature
> wouldn't be right. More importantly, I don't think the person who asked the
> original question is planning to perform Langevin integration. Langevin is
> good to mimic the effects of solvent collisions when running implicit
> solvent and can also be used to improve sampling in some instances, bit it
> wouldn't be very appropriate for his purpose. The gold standard for
> explicit solvent simulations with CHARMM is Verlet (and that's also what
> was used to parametrize the force field).
>
>
> On 08/05/2014 12:52 PM, Hadi Dinpajooh wrote:
>
>> Well, as mentioned in the link NAMD is not well developed if one uses
>> rigid models and Langevin integration:
>>
>> " ... Although /NAMD/ will run with Langevin integration and rigid bonds
>>
>> both active, the equilibrium temperature of the system does not converge
>> to the correct value. Different Langevin equations are needed to produce
>> the correct velocity distribution, which have not yet been added to
>> /NAMD/."
>>
>>
>> Hadi
>>
>> Sent from my iPhone
>>
>> On Aug 5, 2014, at 7:54 AM, Kenno Vanommeslaeghe
>> <kvanomme_at_rx.umaryland.edu <mailto:kvanomme_at_rx.umaryland.edu>> wrote:
>>
>> On 08/05/2014 03:14 AM, Hadi wrote:
>>>
>>>> (2) It is my understanding that the parameters you copy-pasted into
>>>> your e-mail are just "reasonable values" for in case an MD engine or
>>>> methodology is used that does not support rigid water. They won't
>>>> give
>>>> the exact same properties as the true rigid TIP3P model. NAMD,
>>>> however, does support rigid water; assuming the psf is generated
>>>> correctly, all one need to do is put the following line in the NAMD
>>>> input:
>>>> rigidBonds water
>>>> Though if you're using the CHARMM force field, it's actually
>>>> recommended to instead use
>>>> rigidBonds all
>>>> because that's what the force field is parametrized for.
>>>>
>>>>
>>>> I hope it is clear that unlike MC simulations, a rigid model can
>>>> actually
>>>> be slightly flexible in MD simulations.
>>>>
>>>> Hadi
>>>>
>>>
>>> Umm no, provided that no mistakes were made in the set-up of SHAKE
>>> (rigidBonds in NAMD), a rigid model is really rigid in MD. Except for
>>> insignificant numerical deviations related to the SHAKE tolerance. More
>>> info here: http://www.ks.uiuc.edu/Research/namd/1.5/ug/node64.html
>>>
>>>
>

This archive was generated by hypermail 2.1.6 : Thu Dec 31 2015 - 23:21:05 CST