Re: colvar keyword ForceNoPBC

From: Giacomo Fiorin (giacomo.fiorin_at_gmail.com)
Date: Wed Feb 27 2013 - 23:50:16 CST

Hello Nadeem, that keyword is specific to "distance", so it should be
within the "distance" block, not outside.

Bests
Giacomo

On Thu, Feb 28, 2013 at 12:46 AM, Nadeem A. Vellore <vnadeem_at_gmail.com>wrote:

> Dear All,
>
> I tried using the keyword 'forcenopbc on' and got an error :
> colvars: Error: keyword "forcenopbc" is not supported, or not recognized
> in this context. colvars: If this error message is unclear, try recompiling
> with -DCOLVARS_DEBUG. FATAL ERROR: Error in the collective variables
> module: exiting.
>
> is this error due to compilation or mistake in the input command :
> Appreciate your reply.
>
> Nadee
>
> ------------------------------------------
> colvarsTrajFrequency 1000
> colvarsRestartFrequency 4000
>
> colvar {
> name COMDistance
> forceNoPBC on
> outputSystemForce yes
> distance
> {
> group1
> {
> atomnumbers 34 36 38 40 44
> ..
> ..
>

This archive was generated by hypermail 2.1.6 : Wed Dec 31 2014 - 23:20:58 CST