Single point energy calc with gaussian/namd... log file interpretation

From: Stober, Spencer T (spencer.t.stober_at_exxonmobil.com)
Date: Fri Feb 22 2013 - 16:31:01 CST

Hello,

I have performed a single point energy calculation in Gaussian (which I am not highly familiar with). I want to compare the energy results for this molecule with the results from a NAMD simulation of the same molecule in a vacuum using the CHARMM force field.

So, for the NAMD run I have the standard output:

ETITLE: TS BOND ANGLE DIHED IMPRP
          ELECT VDW BOUNDARY MISC KINETIC
          TOTAL TEMP TOTAL2 TOTAL3 TEMPAVG
       PRESSURE GPRESSURE VOLUME PRESSAVG GPRESSAVG

>From this I need the VDW and ELECT energies for my calculations.

The output from the single point energy calculation from the Gaussian log file (for a single molecule) contains this as the energy:

N-N= 2.091731426218D+03 E-N=-9.789529633567D+03 KE= 1.508520754068D+03

I assume this is Nuclear-Nuclear, Electron-Nuclear, and Electron Kinetic energy.

I would appreciate if anyone could comment on how the Gaussian output corresponds to the NAMD output. I.e., does N-N = VDW?, etc.

Thanks for the help, Spence

This archive was generated by hypermail 2.1.6 : Tue Dec 31 2013 - 23:22:58 CST