Unable to reproduce same results in minimization with GBIS

From: Kasam, Vinod (vkasam_at_coh.org)
Date: Thu Sep 13 2012 - 10:52:31 CDT

Dear NAMD users,

I am running a minimizationin NAMD using the parameters shown below. When I ran minimization using the same parameters in two different folders with the same input (protein), I am ending up in different results.
The co-ordinates of the proteins and the energy values after minimization are different. However, if I do not use GBIS (comment out GBIS input parameters), the results are same and just FINE.

I am new to NAMD and I am using NAMD2.8 version, can some explain me why are the results different for the same input if I use GBIS.

Thank you,
Vinod

# MOLECULAR SYSTEM
structure min_WT-chain_D.psf
coordinates min_WT-chain_D.pdb

# FORCE FIELD
paraTypeCharmm on
parameters par_all22_prot_cmap.inp

# APPROXIMATIONS
switching on
switchdist 15
cutoff 16
pairlistdist 17.5
#margin 3
exclude scaled1-4
1-4scaling 1.0
dielectric 3
seed 20111012

#INTEGRATOR
timestep 1.0
nonbondedFreq 1
fullElectFrequency 2
stepspercycle 20

#GBIS - Implicit solvent
GBIS on
solventDielectric 78.5
ionConcentration 0.2
 alphaCutoff 15

# PERIODIC BOUNDARY CONDITIONS
cellBasisVector1 51.76400065422058 0 0
cellBasisVector2 0 45.07099914550781 0
cellBasisVector3 0 0 43.320000648498535
cellOrigin 28.250900268554688 39.77300262451172 7.405788421630859

# WRAPPING
wrapAll on

# OUTPUT
outputname monomerA-crystal-min
dcdfreq 500
xstfreq 10000

outputenergies 10
outputtiming 100
binaryoutput no
binaryrestart yes

# RESTART FILES
restartname res
restartfreq 1000
restartsave yes

# TEMPERATURE CONTROL
temperature 0

minimize 1000

---------------------------------------------------------------------
*SECURITY/CONFIDENTIALITY WARNING:
This message and any attachments are intended solely for the individual or entity to which they are addressed. This communication may contain information that is privileged, confidential, or exempt from disclosure under applicable law (e.g., personal health information, research data, financial information). Because this e-mail has been sent without encryption, individuals other than the intended recipient may be able to view the information, forward it to others or tamper with the information without the knowledge or consent of the sender. If you are not the intended recipient, or the employee or person responsible for delivering the message to the intended recipient, any dissemination, distribution or copying of the communication is strictly prohibited. If you received the communication in error, please notify the sender immediately by replying to this message and deleting the message and any accompanying files from your system. If, due to the security risks, you do not wish to receive further communicatio