From: Shen, Han (han.shen_at_bme.gatech.edu)
Date: Fri Apr 15 2011 - 09:14:11 CDT
Hi all,
I have a problem in colvars. The same program run well on my computer which is Windows. However, when I run the same thing on the supercomputer which is Linux, the error happened every time, said: Error: keyword "group1" is not supported, or not recognized in this context. Distance.in and log file are attached bellow. Would you please help me to take a look and give me some suggestions? Thanks in advance!
*******************************************************************************
*******************************************************************************
Distance.in
colvarsTrajFrequency 2000
colvarsRestartFrequency 20000
colvar {
name AtomDistance
width 0.1
lowerboundary 8.0
upperboundary 15.0
lowerwallconstant 10.0
upperwallconstant 0.2
distance {
group1 {
atomnumbers { 1 5 7 }
}
group2 {
atomnumbers { 342 344 346 }
}
}
}
abf {
colvars AtomDistance
fullSamples 500
hideJacobian
*******************************************************************************
*******************************************************************************
Log file:
colvars: ----------------------------------------------------------------------
colvars: Initializing the collective variables module, version 20091218.
colvars: # analysis = off [default]
colvars: # colvarsTrajFrequency = 2000
colvars: # colvarsRestartFrequency = 20000
colvars: # colvarsTrajAppend = off [default]
colvars: The restart output state file will be "e3k3b_in.restart.colvars.state".
colvars: The final output state file will be "e3k3b_in.colvars.state".
colvars: The trajectory file will be "e3k3b_in.colvars.traj".
colvars: ----------------------------------------------------------------------
colvars: Initializing a new collective variable.
colvars: # name = AtomDistance
colvars: Initializing a new "distance" component.
colvars: # componentCoeff = 1 [default]
colvars: # componentExp = 1 [default]
colvars: # period = 0 [default]
colvars: # wrapAround = 0 [default]
colvars: # forceNoPBC = off [default]
colvars: # oneSiteSystemForce = off [default]
colvars: Initializing atom group "group1".
colvars: Error: keyword "" is not supported, or not recognized in this context.
colvars: If this error message is unclear, try recompiling with -DCOLVARS_DEBUG.
FATAL ERROR: Error in the collective variables module: exiting.
-- Han Shen Wallace H. Coulter Department of Biomedical Engineering Georgia Institute of Technology and Emory University Room 4165, M Building Atlanta, GA 30332 770-676-8397
This archive was generated by hypermail 2.1.6 : Mon Dec 31 2012 - 23:20:08 CST