Re: pairlist i_upper mismatch!

From: Schreiner Eduard (eschrein_at_ks.uiuc.edu)
Date: Sat Nov 22 2008 - 00:41:08 CST

hi,
just a remark/question:
why you are using a margin of 50?!
is it really necessary? usually, it should not.
Another thing, I saw: you are restarting velocities, but
the loop at the end does reset the thermostat (but not the velocities).
Is this behavior intended or do I miss something?
Finally, there is a line

> cutoff 12.switching on

Is it just a typo in the mail, or is the line really like that?

Same, in

> timestep 2.0 ;# 2fs/steprigidBonds all

This one, could maybe mess up your structure after some integration
steps.

eddi

On Nov 22, 2008, at 12:20 AM, Diego Alejandro Vargas wrote:

> Peter,
> I couldn't find any atoms that had the same coordinates. In VMD
> everything looks normal, and having checked all coordinates in
> the .pdb file no atoms show up within 0.5A or less of each other.
>
> Do you have any other idea of why I may be getting this error
> message? I am pasting my configuration file below in case it may be
> of help.
>
> Thank you,
> Diego
> ____________________________________________________________
>
> #############################################################
> ## ADJUSTABLE PARAMETERS ##
> #############################################################
>
> structure /wt_fascin_wb.psf
> coordinates /wt_fascin_wb.pdb
> bincoordinates /wt_fascin_wb_mn.restart.coor
>
> binvelocities /wt_fascin_wb_mn.restart.vel
>
> extendedSystem /wt_fascin_wb_mn.restart.xsc
>
> set temperature 310
> set outputname ***
>
> firsttimestep 0
>
>
> #############################################################
> ## SIMULATION PARAMETERS ##
> #############################################################
>
> # Input
> paraTypeCharmm on
> parameters ../common/par_all27_prot_lipid.inp
>
>
> # Force-Field Parametersexclude scaled1-4
> 1-4scaling 1.0
> cutoff 12.switching on
> switchdist 10.
> pairlistdist 13.5
>
>
> # Integrator Parameters
> timestep 2.0 ;# 2fs/steprigidBonds all
> nonbondedFreq 1
> fullElectFrequency 2
> stepspercycle 10
>
> margin 50.0
>
> # Constant Temperature Control
> langevin on ;# do langevin dynamics
> langevinDamping 5 ;# damping coefficient (gamma) of 5/ps
> langevinTemp 1
> langevinHydrogen off ;# don't couple langevin bath to hydrogens
>
>
> # Periodic Boundary Conditions
> # extendedSystem used.
>
> wrapAll on
>
> # PME (for full-system periodic electrostatics)
> PME yes
> PMEGridSizeX 100
> PMEGridSizeY 128
> PMEGridSizeZ 100
>
>
> # Constant Pressure Control (variable volume)
> useGroupPressure yes ;# needed for rigidBonds
> useFlexibleCell no
> useConstantArea no
>
> langevinPiston on
> langevinPistonTarget 1.01325 ;# in bar -> 1 atm
> langevinPistonPeriod 100.
> langevinPistonDecay 50.
> langevinPistonTemp 1
>
>
> # Output
> outputName $outputname
>
> restartfreq 500 ;# 500steps = every 1ps
> dcdfreq 250
> xstFreq 250
> outputEnergies 100
> outputPressure 100
>
>
> #############################################################
> ## EXECUTION SCRIPT ##
> #############################################################
>
> # Gradual temperature increase:
> run 500
> for {set i 10} {$i <= $temperature} {incr i 10} {
> langevinTemp $i
> langevinPistonTemp $i
> run 500
> }
>
> run 250000 ;# 500ps

=====================================================
Eduard Schreiner
Theoretical and Computational Biophysics Group