From: Ugur Akgun (ugur_iowa_at_hotmail.com)
Date: Mon Feb 26 2007 - 16:32:24 CST
Hi All;
I have a water, protein, and CO2 system. The system successfully minimizes 
but at the first step of MD equilibration it gives the error I pasted below. 
Let me summarize what i did to debug this;
- I don't use useFlexibleCell feature, but when I added "useFlexibleCell no" 
to the input file.. Doing this does not change the error.
- I put a term "margin 2.5" and I changed it up to 8... still the same 
error...
- The water, protein, lipid system equilibrates successfully, The problem 
comes from CO2..
- I believe it is CO2 parameter file, I'd really appreciate any ideas, and a 
nice CO2 parameter file..
thanks a lot
cheers
ugur akgun
ETITLE:      TS           BOND          ANGLE          DIHED          IMPRP  
              ELECT            VDW       BOUNDARY           MISC        
KINETIC               TOTAL           TEMP         TOTAL2         TOTAL3     
    TEMPAVG            PRESSURE      GPRESSURE         VOLUME       PRESSAVG 
      GPRESSAVG
ENERGY:       0     13188.8073     18461.4224     12561.1557       129.1724  
       -413297.4367     10436.7914         0.0000         0.0000  
99999999.9999       99999999.9999  99999999.9999  99999999.9999  
99999999.9999  99999999.9999       99999999.9999  99999999.9999   
1408176.0000  99999999.9999  99999999.9999
ERROR: Margin is too small for 9 atoms during timestep 1.
ERROR: Incorrect nonbonded forces and energies may be calculated!
FATAL ERROR: Periodic cell has become too small for original patch grid!
Possible solutions are to restart from a recent checkpoint,
increase margin, or disable useFlexibleCell for liquid simulation.