Re: Re: Re: Large energy fluctuation

From: Marcos Sotomayor (sotomayo_at_ks.uiuc.edu)
Date: Wed May 31 2006 - 21:48:37 CDT

Have a look at
http://www.ks.uiuc.edu/Research/namd/mailing_list/namd-l/3407.html

likely your are using a multiple time stepping algorithm, and that's why
you see changes in the electrostatic energy.

Marcos

On Wed, 1 Jun 2005, Sting wrote:

> Hi Cesar,
> Thank you for suggestion.This system is a super-helix consisted of
  three chains,about 110 X 3 residues.I have performed a 10,000 steps
  minimization and 500ps MD(with CA fixed),then another 500ps free MD was
  performed.While minimization,the energy fluctuation(sorry,I shuld correct
  myself,that the changing energy is not VDW but Elect energy) didn't
  occur,but both the constrain MD and free MD presented the energy shift as
  said before.
> By the way,during solvating the protein,we set the waters departing 3.3 Å from protein (defaut is 2.4 Å),and then did NTV MD. So that, at some specific positions near the protein, huge water holes occured.Did the Elect Energy shift has any relationship with this?
> Thank you for your time.
>
> Sting
>
>
> ======= 2006-06-01 02:12:52 :=======
>
>> May be you should better equilibrate the system before running MD.
>> Regards
>> Cesar
>>
>> Sting wrote:
>>
>>> Dear all
>>> When I performed a MD run with NAMD,every things went well,but when analyzing the energy of the system,I noticed that there was a large fluctuation between every two sequential steps,something like: step VDW energy
>>> 259970 -226049.7557
>>> 259980 -38243.0418
>>> 259990 -226001.2423
>>> 260000 -38106.4633
>>> I wonder what I should understand this.
>>> Any suggestion will be appreciated.
>>>
>>>
>>>
>>>
>>>         Sting
>>>         stg1979_at_emails.bjut.edu.cn
>>>           2005-04-08
>>>
>>>
>
>
>

This archive was generated by hypermail 2.1.6 : Wed Feb 29 2012 - 15:43:40 CST