Hi Martin,
Likely the problem is caused because you are trying to increase the 
temperature gradually while you have Langevin Temperature control on. 
Turn off Langevin, heat the system gradually, and then turn on Langevin in 
your next run to keep the temperature of your system steady.
Marcos
On Fri, 21 Apr 2006, Martin Loewer wrote:
> Hello,
>
> when starting a dynamics simulation, minimization runs well and it always 
> (tried serveral times) runs until setp 1000 and produces the following error 
> message (end of log file):
>
> WRITING COORDINATES TO DCD FILE AT STEP 1000
> WRITING COORDINATES TO RESTART FILE AT STEP 1000
> FINISHED WRITING RESTART COORDINATES
> WRITING VELOCITIES TO RESTART FILE AT STEP 1000
> FINISHED WRITING RESTART VELOCITIES
> TCL: Setting parameter reassignFreq to 100
> FATAL ERROR: Setting parameter reassignFreq from script failed!
>
> Stack Traceback:
> [0] CmiAbort+0x51  [0x734751]
> [1] _Z8NAMD_diePKc+0x63  [0x49ab63]
> [2] _ZN13SimParameters9scriptSetEPKcS1_+0x4be  [0x66dea6]
> [3] _ZN4Node11scriptParamEP14ScriptParamMsg+0x25  [0x617a25]
> [4] _ZN12CkIndex_Node32_call_scriptParam_ScriptParamMsgEPvP4Node+0x12 
> [0x6179fa]
> [5] CkDeliverMessageFree+0x30  [0x6cfe38]
> [6] _Z15_processHandlerPvP11CkCoreState+0x44a  [0x6d24ca]
> [7] CmiHandleMessage+0x26  [0x73b1ae]
> [8] CsdScheduleForever+0x4b  [0x73b30b]
> [9] CsdScheduler+0x1c  [0x73c98c]
> [10] _ZN7BackEnd7suspendEv+0xe  [0x4a1536]
> [11] _ZN7BackEnd7barrierEv+0xe  [0x4a14fe]
> [12] _ZN9ScriptTcl12setParameterEPKcS1_+0x137  [0x657a27]
> [13] _ZN9ScriptTcl9Tcl_paramEPvP10Tcl_InterpiPPc+0x18c  [0x65697c]
> [14] TclInvokeStringCommand+0x91  [0x758d78]
> [15] /home/loewer/bin/NAMD/namd2 [0x78ebc8]
> [16] /home/loewer/bin/NAMD/namd2 [0x78e9e1]
> [17] Tcl_EvalEx+0x176  [0x78f20b]
> [18] Tcl_EvalFile+0x134  [0x786c14]
> [19] _ZN9ScriptTcl3runEPc+0x1c  [0x656294]
> [20] main+0x222  [0x49dae2]
> [21] __libc_start_main+0xda  [0x2aaaab12a5aa]
> [22] _ZStlsISt11char_traitsIcEERSt13basic_ostreamIcT_ES5_c+0x5a  [0x49a4aa]
>
> This looks like a bug in the program to me. Maybe I can change my config file 
> (see below) to avoid this.
>
> Sincerly,
> Martin Loewer
>
> #############################################################
> ## ADJUSTABLE PARAMETERS                                   ##
> #############################################################
> structure          sp_wb.psf
> coordinates        sp_wb.pdb
> set temperature    310
> set outputname     sp_wb_eq
> firsttimestep      0
> #############################################################
> ## SIMULATION PARAMETERS                                   ##
> #############################################################
> # Input
> paraTypeCharmm	    on
> parameters          par_all27_prot_lipid.inp temperature         $temperature
>
> # Force-Field Parameters
> exclude             scaled1-4
> 1-4scaling          1.0
> cutoff              12.
> switching           on
> switchdist          10.
> pairlistdist        13.5
>
> # Integrator Parameters
> timestep            2.0  ;# 2fs/step
> rigidBonds          all  ;# needed for 2fs steps
> nonbondedFreq       1
> fullElectFrequency  2  stepspercycle       10
>
> # Constant Temperature Control
> langevin            on    ;# do langevin dynamics
> langevinDamping     5     ;# damping coefficient (gamma) of 5/ps
> langevinTemp        $temperature
> langevinHydrogen    off    ;# don't couple langevin bath to hydrogens
>
> # Periodic Boundary Conditions
> cellBasisVector1    82.    0.   0.
> cellBasisVector2     0.   90.   0.
> cellBasisVector3     0.    0   90.
> cellOrigin          29.0915279388 -18.3676776886 17.4208488464
> wrapAll             on
>
> # PME (for full-system periodic electrostatics)
> PME                 yes
> PMEGridSizeX        96
> PMEGridSizeY        96
> PMEGridSizeZ        96
>
> # Constant Pressure Control (variable volume)
> useGroupPressure      yes ;# needed for rigidBonds
> useFlexibleCell       no
> useConstantArea       no
>
> langevinPiston        on
> langevinPistonTarget  1.01325 ;#  in bar -> 1 atm
> langevinPistonPeriod  100.
> langevinPistonDecay   50.
> langevinPistonTemp    $temperature
>
> # Output
> outputName          $outputname
> restartfreq         500     ;# 500steps = every 1ps
> dcdfreq             250
> xstFreq             250
> outputEnergies      100
> outputPressure      100
> #############################################################
> ## EXECUTION SCRIPT                                        ##
> #############################################################
> # Minimization
> minimize            1000
>
> ## Heating Process
> reassignFreq 100
> reassignTemp 31
> reassignIncr 31
> reassignHold $temperature
> reinitvels          31
> run 3500 ;# 7ps
>