AMBER force field parameters

AMBER format PARM file and coordinate file can be read by NAMD, which allows one to use AMBER force field to carry out all types of simulations that NAMD has supported. NAMD can read PARM files in either the format used in AMBER 6 or the new format defined in AMBER 7. The output of the simulation (restart file, DCD file, etc.) will still be in traditional format that has been used in NAMD.

Caveat:

1. Polarizable parameters in AMBER are not supported.

2. NAMD does not support the 10-12 potential terms in some old AMBER versions. When non-zero 10-12 parameter is encountered in PARM file, NAMD will terminate.

3. NAMD has several exclusion policy options, defined by exclude. The way AMBER dealing with exclusions corresponds to the ``scaled1-4'' in NAMD. So for simulations using AMBER force field, one would specify ``exclude scaled1-4'' in the configuration file, and set 1-4scaling to the inverse value of SCEE as would be used in AMBER.

4. NAMD does not read periodic box lengths in PARM or coordinate file. They must be explicitly specified in NAMD configuration file.

5. By default, NAMD applies switching functions to the non-bond interactions within the cutoff distance, which helps to improve energy conservation, while AMBER does not use switching functions so it simply truncates the interactions at cutoff. However, if ``authentic'' AMBER cutoff simulations are desired, the switching functions could be turned off by specifying ``switching off'' in NAMD configuration file.

6. NAMD and AMBER may have different default values for some parameters (e.g., the tolerance of SHAKE). One should check other sections of this manual for accurate descriptions of the NAMD options.

Following are two examples of the NAMD configuration file to read AMBER force field and carry out simulation. They may help users to select proper NAMD options for AMBER force field. For the convenience of AMBER users, the AMBER 6 sander input files are given in the left for comparison, which would accomplish similar tasks in AMBER.

Example 1: Non-periodic boundary system, cutoff simulation

---AMBER----      ---NAMD---

 TITLE
 &cntrl
  ntb=0, igb=2,   # non-periodic, use cutoff for non-bond
  nstlim=1000,    numsteps       1000  # Num of total steps
  ntpr=50,        outputEnergies 50  # Energy output frequency
  ntwr=50,        restartfreq    50  # Restart file frequency
  ntwx=100,       DCDfreq        100  # Trajectory file frequency
  dt=0.001,       timestep       1  # in unit of fs (This is default)
  tempi=0.,       temperature    0  # Initial temp for velocity assignment
  cut=10.,        cutoff         10
                  switching      off  # Turn off the switching functions
  scee=1.2,       exclude        scaled1-4
                  1-4scaling     0.833333  # =1/1.2, default is 1.0
  scnb=2.0        scnb           2  # This is default
 &end
                  amber          on  # Specify this is AMBER force field
                  parmfile       prmtop  # Input PARM file
                  ambercoor      inpcrd  # Input coordinate file
                  outputname     md  # Prefix of output files

Example 2: Periodic boundary system, PME, NVE ensemble, using SHAKE algorithm

---AMBER----      ---NAMD---

 TITLE
 &cntrl
  ntc=2, ntf=2,   # SHAKE to the bond between each hydrogen and it mother atom
                  rigidBonds     all
  tol=0.0005,     rigidTolerance 0.0005  # Default is  0.00001
  nstlim=500,     numsteps       500  # Num of total steps
  ntpr=50,        outputEnergies 50  # Energy output frequency
  ntwr=100,       restartfreq    100  # Restart file frequency
  ntwx=100,       DCDfreq        100  # Trajectory file frequency
  dt=0.001,       timestep       1  # in unit of fs (This is default)
  tempi=300.,     temperature    300  # Initial temp for velocity assignment
  cut=9.,         cutoff         9
                  switching      off  # Turn off the switching functions
 &end
 &ewald           PME            on  # Use PME for electrostatic calculation
                  # Orthogonal periodic box size
  a=62.23,        cellBasisVector1   62.23  0  0
  b=62.23,        cellBasisVector2   0  62.23  0
  c=62.23,        cellBasisVector3   0  0  62.23
  nfft1=64,       PMEGridSizeX   64
  nfft2=64,       PMEGridSizeY   64
  nfft3=64,       PMEGridSizeZ   64
  ischrgd=1,      # NAMD doesn't force neutralization of charge
 &end
                  amber          on  # Specify this is AMBER force field
                  parmfile       FILENAME  # Input PARM file
                  ambercoor      FILENAME  # Input coordinate file
                  outputname     PREFIX  # Prefix of output files
                  exclude        scaled1-4
                  1-4scaling     0.833333  # =1/1.2, default is 1.0


next up previous contents index